{"id":3344,"date":"2026-11-11T13:15:23","date_gmt":"2026-11-11T12:15:23","guid":{"rendered":"https:\/\/neximed.hu\/2026\/11\/11\/handpiece-maintenance-extend-lifespan\/"},"modified":"2026-11-13T11:10:09","modified_gmt":"2026-11-13T10:10:09","slug":"handpiece-maintenance-extend-lifespan","status":"publish","type":"post","link":"https:\/\/neximed.hu\/en\/2026\/11\/11\/handpiece-maintenance-extend-lifespan\/","title":{"rendered":"Handpiece maintenance: how to extend their lifespan"},"content":{"rendered":"<p>Dental handpieces, contra-angles and turbines are among the most expensive instruments in a practice and are used every day. Their lifespan depends largely on whether the team consistently cleans, lubricates and sterilises them after each treatment. Regular maintenance not only reduces repair costs but also supports patient safety.<\/p>\n<h2>Immediately after treatment<\/h2>\n<p>At the end of treatment, before removing the bur or head, run the handpiece with water and air for a few seconds to flush debris out of the internal channels. Then wipe the outer surface with an alcohol-based disinfectant wipe approved by the manufacturer. Never immerse a handpiece in disinfectant solution unless the manufacturer explicitly allows it.<\/p>\n<h2>Internal cleaning and lubrication<\/h2>\n<p>Before sterilisation, the handpiece must also be cleaned and lubricated internally, using a dedicated handpiece oil spray or an automatic maintenance unit. Apply the oil through the connector specified by the manufacturer, then remove the excess by briefly running or blowing out the handpiece. Too little oil accelerates bearing wear, while too much can bake on during sterilisation.<\/p>\n<h2>Sterilisation<\/h2>\n<ul><li>Pack the handpiece in a sterilisation pouch and label it with the date.<\/li><li>Sterilise it in a class B autoclave at the temperature specified by the manufacturer (typically 134 \u00b0C).<\/li><li>Let it cool in the pouch after the cycle and store it in a dry, dust-free place.<\/li><li>Check sterilisation effectiveness regularly with indicators and tests.<\/li><\/ul>\n<h2>Common mistakes<\/h2>\n<p>The most frequent problems are skipped lubrication, incorrect air pressure, running without a bur and using damaged burs. If a handpiece becomes noisier, heats up, vibrates or the bur no longer locks securely, stop using it and send it for service. Having several handpieces per treatment unit leaves enough time for a complete maintenance cycle.<\/p>\n<h2>What you will need<\/h2>\n<ul><li>handpiece oil spray or a maintenance unit;<\/li><li>alcohol-based surface disinfectant wipes;<\/li><li>sterilisation pouches and rolls;<\/li><li>sterilisation monitoring indicators and tests.<\/li><\/ul>\n<p>You will find products for maintenance and sterilisation in the <a href=\"https:\/\/neximed.hu\/en\/product-category\/fertotlenites-es-sterilizalas\/\">Disinfection &amp; sterilization<\/a> category, and handpieces and devices in <a href=\"https:\/\/neximed.hu\/en\/product-category\/muszerek-es-berendezesek\/\">Devices &amp; equipment<\/a>.<\/p>\n\n<div class=\"nx-related\"><h3>Related product categories<\/h3><ul><li><a href=\"https:\/\/neximed.hu\/en\/product-category\/muszerek-es-berendezesek\/\">Devices &#038; equipment<\/a><\/li><li><a href=\"https:\/\/neximed.hu\/en\/product-category\/fertotlenites-es-sterilizalas\/\">Disinfection &#038; sterilization<\/a><\/li><\/ul><p>Questions about a product? Message us on WhatsApp: +36 70 398 2552.<\/p><\/div>","protected":false},"excerpt":{"rendered":"<p>Turbines and contra-angles are expensive. Daily cleaning and lubrication make a big difference to their lifespan.<\/p>","protected":false},"author":4,"featured_media":3311,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"page_builder":"","footnotes":""},"categories":[278],"tags":[],"class_list":["post-3344","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-english"],"_links":{"self":[{"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/posts\/3344","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/comments?post=3344"}],"version-history":[{"count":2,"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/posts\/3344\/revisions"}],"predecessor-version":[{"id":3388,"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/posts\/3344\/revisions\/3388"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/media\/3311"}],"wp:attachment":[{"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/media?parent=3344"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/categories?post=3344"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/neximed.hu\/en\/wp-json\/wp\/v2\/tags?post=3344"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}